Plan the whole colo cage, from floor plan to cable label.
Lay out the cage, cabinets and racks, A and B power, cable pathways, structured cabling and labels in one project. Then hand your installer the drawings and schedules to build it.
Most teams juggle a drawing tool, a rack spreadsheet, a cable list and a label file. Ampora DC keeps them in one design, so a change in one place shows up everywhere.
Cage and aisles
Draw the cage walls, columns and obstructions, then mark hot and cold aisles. Work in metres or feet.
Cabinets and racks
Pick cabinet models from the catalog, place them in rows, and set which way each front faces.
Devices by rack unit
Mount switches, servers and patch panels RU by RU, front or rear, and review rails and mounting.
A and B power
Give each cabinet its PDUs and each device its Leg A and Leg B feed. Watts and VA stay separate.
Cable pathways
Route cable tray, fiber tray, cable runway and conduit, overhead or underfloor, on the room plan.
Structured cabling
Connect copper and fiber, port to port. Cable type suggestions come with their reach and source, and lengths show in metres and feet.
Labels
TIA-606 names for cabinets, panels, ports, cables and PDUs, with import files for Panduit, Brady, DYMO and Brother label software.
Installer pack
One PDF for the crew: floor plan to scale, cabinet elevations, cable schedule and power by cabinet.
How it works
1
Room and aisles
Draw the cage, its columns and its hot and cold aisles.
2
Cabinets and devices
Place each cabinet, set its front, and fill it RU by RU.
3
Power
Add PDUs and give every device its Leg A and Leg B feed.
4
Pathways and cabling
Lay out trays, then connect ports with the right cable.
Place a cabinet, set the way its front faces, then mount each device in its rack units, front or rear. Open space and crowded cabinets are easy to spot, and the same elevation goes into the installer pack.
Cabinet models from the catalog, with their sizes
Rails and mounting reviewed for every device
A01 · front · 42 RU
42
35
30
25
20
15
10
5
1
A01-PP42
A01-SW141
A01-SW240
A01-SRV0137-38
A01-SRV0235-36
A01-SRV0333-34
A01-SRV0431-32
A01-SRV0529-30
A01-SRV0627-28
A01-SRV0725-26
A01-SRV0823-24
A01-SRV0921-22
A01-SRV1019-20
A01-SRV1117-18
A01-SRV1215-16
A01-STO19-12
A01-STO25-8
Power
A and B power for every device.
Give each cabinet its PDUs and each device its Leg A and Leg B feed. Watts and VA stay separate, and a device with no power figure yet stays visible instead of being guessed.
Cabinet totals and any missing feed
Power by cabinet, ready for the electrician
Power by cabinet · A01
RU
Device
Power
Leg A
Leg B
42
A01-PP
not set
none
none
41
A01-SW1
350 W
A01-PDU-A
A01-PDU-B
40
A01-SW2
350 W
A01-PDU-A
A01-PDU-B
37-38
A01-SRV01
650 W
A01-PDU-A
A01-PDU-B
35-36
A01-SRV02
650 W
A01-PDU-A
A01-PDU-B
+ 12 more devices
A01 total · 17 devices
10,300 W + 1 not set
Pathways and structured cabling
Trays, connections and cables, end to end.
Draw cable tray, fiber tray, runway and conduit on the room plan, overhead or underfloor. Connect ports across the cage, and pick each cable type from suggestions that name their source and reach.
Copper and fiber, with connector types at both ends
Every length in metres and feet
Cable schedule · sample cage
From
To
Cable type
Length
Tray route
A01-41:01
A02-42:01
Cat 6A · RJ45
3.0 m9.8 ft
Tray A
A01-40:05
B01-40:05
OM4 fiber · LC
10.0 m32.8 ft
Tray A, Spine tray, Tray B
A02-41:49
A01-40:02
OM4 fiber · LC
4.0 m13.1 ft
Tray A
B03-41:49
B01-40:03
OM4 fiber · LC
4.0 m13.1 ft
Tray B
Labels
Labels named the way installers expect.
Every cabinet, panel, port, cable and PDU gets a TIA-606 name from the design itself, so the label always matches the drawing. Cables show both ends, near end first.
Wrap, flag and tag styles
Import files for Panduit, Brady, DYMO and Brother label software
Cable, near endA01-35:05B04-20:05
Cable, far endB04-20:05A01-35:05
Panel ports010203040506
CabinetA01
PDUA01-PDU-ALeg A
Installer pack
Hand the crew what they need to build it.
Download one printable PDF with a title block on every sheet, plus plain spreadsheets the crew can sort and check off. Cable lengths show metres and feet on every row.
It is a design package for review: every sheet is marked not for construction.
PDF
Installer pack
Floor plan, elevations, cable schedule and power, US Letter
PDF · SVG
Floor plan
To a stated scale, dimensions in m and ft-in
PDF · SVG
Cabinet elevations
Front and rear, every device in its rack units
PDF · CSV
Cable schedule
From and to, cable type, connectors, length, tray route
PDF · CSV
Power by cabinet
Leg A and Leg B PDU for each device, cabinet totals
CSV
Cabinet list and devices by cabinet
Positions, sizes, rack units, faces
Built on industry standards.
The room plan, connection names and cable type suggestions follow the published standards that installers and colocation providers already use.
TIA-942-C
Room layout
Cabinet fronts face a cold aisle and their backs a hot aisle, the arrangement the standard sets out.
TIA-606-D
Names and labels
Each connection is named by its two ends: cabinet, rack unit and port, such as A01-35:05 to B04-20:05.
TIA-568 · IEEE 802.3
Cables
Cable type suggestions come from the standards, each with its reach and source. For example, 10GBASE-T runs up to 100 m on Cat 6A.
Each cable type suggestion names its source and reach, and you can change it. TIA and IEEE publish these standards; they have not certified or endorsed Ampora DC. Printer manufacturers are named only to show which label files the app writes.
See it with a sample cage.
Open the demo and plan a few racks yourself, from the room to the labels. It resets every night.